mailbox: pcc: Drop unnecessary endianness conversion of pcc_hdr.flags

The Sparse static checker flags a type mismatch warning related to
endianness conversion:

  |  warning: incorrect type in argument 1 (different base types)
  |     expected restricted __le32 const [usertype] *p
  |     got unsigned int *

This is because an explicit endianness conversion (le32_to_cpu()) was
applied unnecessarily to a pcc_hdr.flags field that is already in
little-endian format.

The PCC driver is only enabled on little-endian kernels due to its
dependency on ACPI and EFI, making the explicit conversion unnecessary.

The redundant conversion occurs in pcc_chan_check_and_ack() for the
pcc_hdr.flags field. Drop this unnecessary endianness conversion of
pcc_hdr.flags.

Also drop the redundant PCC_ACK_FLAG_MASK definition and use the
more appropriate and already defined PCC_CMD_COMPLETION_NOTIFY.

Acked-by: Huisong Li <lihuisong@huawei.com>
Tested-by: Adam Young <admiyo@os.amperecomputing.com>
Signed-off-by: Sudeep Holla <sudeep.holla@arm.com>
Signed-off-by: Jassi Brar <jassisinghbrar@gmail.com>
This commit is contained in:
Sudeep Holla
2025-03-13 15:28:49 +00:00
committed by Jassi Brar
parent cf1338c0e0
commit 29237e6df4
2 changed files with 1 additions and 2 deletions

View File

@@ -292,7 +292,7 @@ static void check_and_ack(struct pcc_chan_info *pchan, struct mbox_chan *chan)
*
* The PCC master subspace channel clears chan_in_use to free channel.
*/
if (le32_to_cpup(&pcc_hdr.flags) & PCC_ACK_FLAG_MASK)
if (pcc_hdr.flags & PCC_CMD_COMPLETION_NOTIFY)
pcc_send_data(chan, NULL);
else
pcc_chan_reg_read_modify_write(&pchan->cmd_update);

View File

@@ -32,7 +32,6 @@ struct pcc_mbox_chan {
#define PCC_CMD_COMPLETION_NOTIFY BIT(0)
#define MAX_PCC_SUBSPACES 256
#define PCC_ACK_FLAG_MASK 0x1
#ifdef CONFIG_PCC
extern struct pcc_mbox_chan *